CHLORINE SAFETY RELIEF VALVES
INTERNAL VALVE
Fort Vale offers 3 choices of Safety Relief Valves for Chlorine Service. Choose between: External (Shear-Off)/ External (Non-Shear-Off) and an Internal Safety Valve. All three-options feature innovative safety and sealing designs as well as significantly higher flows
reverse-acting burst disc
USED IN BOTH EXTERNAL & INTERNAL SAFEY VALVES
UPSIDE DOWN DISC -
Can absorb 90% max allowable working pressure (MAWP) pressure cycling without fatigue indefinitely
Standard discs become fatigued after 80% MAWP pressure cycling (3-4 times)
Non-Fragmenting
Disc petals do not interfere with safety valve
Sealed with 2x primary & 1x secondary O-Rings